4WRPEH10 F1 High‑Speed Proportional Directional Valve
4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection

4WRPEH10 F1 High‑Speed Proportional Directional Valve <br>4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection
Details
BOKIN 4WRPEH10 F1 is a large‑flow direct‑acting high‑speed proportional directional valve with integrated OBE and 4‑20 mA current‑loop control. Featuring built‑in cable‑break monitoring and strong anti‑EMI performance for long‑distance signal transmission. It matches dimensional, electrical‑interface and hydraulic‑performance specifications of equivalent Rexroth 4WRPEH10 F1 for seamless drop‑in installation.

Core Specifications:
NG10 Size | 4‑20 mA F1 Interface | Cable‑Break Monitoring | 350 Bar | <10 ms Response | Optional IO‑Link | 12‑Month Warranty
Category
Type 4WRPEH Proportional Valve
Share to
Send Inquiry
Product Details

Bokin Electro-Hydraulic Technology (Foshan) Co., Ltd. is one of the leading manufacturers and suppliers of 4WRPEH10 F1 High‑Speed Proportional Directional Valve
4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection in China. If you're going to wholesale bulk durable 4WRPEH10 F1 High‑Speed Proportional Directional Valve
4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection made in China, welcome to get pricelist from our factory. All customized products are with high quality and competitive price.

 

 

Key Specifications At a Glance

 

 

Parameter Value
Nominal Size NG10 (Component Series 3X)
Mounting Standard ISO 4401‑05‑04‑0‑05
Max Operating Pressure (A/B/P ports) 350 bar
Max Operating Pressure (T port) 250 bar
Rated Flow (Δp = 35 bar per control edge) 50 – 100 L/min
Control Signal F1 interface, 4‑20 mA current‑loop input
Input Resistance 200 Ω
Max Allowable Load Resistance 500 Ω
Cable‑Break Monitoring Yes (triggered below 2 mA, output shutdown)
Optional Digital Interface IO‑Link (Industry 4.0 ready)
Dynamic Response Time < 10 ms
Hysteresis ≤ 0.2%
Response Sensitivity < 0.05%
Safety Rating (with IO‑Link) PL d, Category 3 per EN 13849‑1
Pilot Oil Demand None (direct‑acting structure)
Supply Voltage 24 VDC (19 – 36 VDC range)
Protection Class IP65 (correctly mounted connector)
Ambient Temperature -20°C to +60°C
CE Compliance MD 2006/42/EC, EN ISO 12100:2010, EMC 2014/30/EU, RoHS 2011/65/EU

 

 

 

Available Configurations

 

 

Select the flow rating and spool type for your system:

 

Model Number

Rated Flow

Spool Type

Quick Action

4WRPEH 10 C B50L-3X/M/24F1

50 L/min

Standard zero overlap (C)

Inquire Now

4WRPEH 10 C B100L-3X/M/24F1

100 L/min

Standard zero overlap (C)

Inquire Now

4WRPEH 10 C1 B50L-3X/M/24F1

50 L/min

Underlap (C1)

Inquire Now

4WRPEH 10 C1 B100L-3X/M/24F1

100 L/min

Underlap (C1)

Inquire Now

4WRPEH 10 C3 B50L-3X/M/24F1

50 L/min

Overlap (C3)

Inquire Now

4WRPEH 10 C3 B100L-3X/M/24F1

100 L/min

Overlap (C3)

Inquire Now

4WRPEH 10 C4 B50L-3X/M/24F1

50 L/min

Heavy overlap (C4)

Inquire Now

4WRPEH 10 C4 B100L-3X/M/24F1

100 L/min

Heavy overlap (C4)

Inquire Now

 

Need a custom spool profile or special configuration? Send us your requirements → Get Custom Solution

 

 

 

Product Key Advantages

 

1. Strong Anti‑Interference for Long‑Distance Large‑Flow Control

The 4‑20 mA current‑loop signal delivers stable transmission over long cable runs and maintains immunity against EMI from motors and frequency converters. Built‑in cable‑break monitoring automatically shuts down output stage at signal current below 2 mA to prevent uncontrolled machine motion. Optimized for medium‑to‑large flow (50‑100 L/min) heavy‑duty hydraulic equipment in electrically‑noisy production environments.

2. Hassle‑Free Direct Interchangeability

Manufactured strictly to ISO 4401‑05‑04‑0‑05 NG10 mounting dimensions, with identical port layout and F1 electrical pin‑out matching Rexroth 4WRPEH10 F1. Direct drop‑in installation without manifold re‑machining or rewiring, minimizing retrofit downtime and project costs.

3. Servo‑Grade Medium‑Large‑Flow Precision Control

Servo‑quality matched spool‑and‑sleeve assembly achieves hysteresis ≤0.2% and excellent temperature stability (zero‑shift <1% over Δϑ = 40 °C). It guarantees repeatable closed‑loop position, velocity and pressure regulation for large‑capacity hydraulic test rigs and forming machinery.

4. Safe & Energy‑Efficient Industry‑4.0‑Ready Design

Direct‑acting construction eliminates pilot‑oil supply requirements to cut system energy consumption and piping complexity. Spring‑centered spool returns to defined fail‑safe neutral position upon power loss or cable‑break fault. Optional IO‑Link interface enables remote parameter setting, real‑time condition monitoring and safety shut‑off up to PL d / Category 3 according to EN 13849‑1.

 

 

 

Compatibility Reference

 

 

Corresponding Rexroth Model

BOKIN Equivalent Model

Core Match Points

4WRPEH 10 C B50L-3X/M/24F1 4WRPEH 10 C B50L-3X/M/24F1 Same NG10 ISO mounting, 4‑20 mA F1 interface, cable‑break protection, large‑flow hydraulic performance
4WRPEH 10 C B100L-3X/M/24F1 4WRPEH 10 C B100L-3X/M/24F1
4WRPEH 10 C1 B50L-3X/M/24F1 4WRPEH 10 C1 B50L-3X/M/24F1
4WRPEH 10 C1 B100L-3X/M/24F1 4WRPEH 10 C1 B100L-3X/M/24F1
4WRPEH 10 C3 B50L-3X/M/24F1 4WRPEH 10 C3 B50L-3X/M/24F1
4WRPEH 10 C3 B100L-3X/M/24F1 4WRPEH 10 C3 B100L-3X/M/24F1
4WRPEH 10 C4 B50L-3X/M/24F1 4WRPEH 10 C4 B50L-3X/M/24F1
4WRPEH 10 C4 B100L-3X/M/24F1 4WRPEH 10 C4 B100L-3X/M/24F1

More models are available; please contact us for additional model options.

 

Note: For system configuration reference only. BOKIN is an independent brand. Please verify specifications before installation.

 

 

 

Typical Applications

 

 

  • Large‑workshop production lines with long‑distance hydraulic wiring
  • Medium‑large hydraulic test rigs & fatigue test systems under heavy EMI
  • Metallurgical auxiliary equipment and outdoor‑capable hydraulic machinery
  • Medium‑large injection‑molding & forming machines with remote control cabinets
  • Industrial hydraulic stations requiring stable 4‑20 mA current‑loop control
  • Safety‑critical hydraulic circuits requiring PL d protection level

 

Need current loop control for long-distance wiring?

View 4WRPEH10 A1 (±10V) →

Need larger flow capacity?

View 4WRPEH6 F1 (NG6) →

 

 

Installation & Commissioning Guidelines

 

Installation Notes

  1. Thoroughly clean all oil ports and connecting surfaces before installation to prevent contaminants from entering the valve body.
  2. Confirm the control signal type (4‑20 mA current‑loop) and power‑supply voltage match the valve nameplate specifications before wiring. Use shielded twisted‑pair cables for signal wiring; ground shield at one end. Ensure total loop resistance stays ≤500 Ω.
  3. Tighten mounting bolts evenly to recommended torque to avoid valve‑body deformation and internal leakage, complying with ISO 4401‑05‑04‑0‑05 NG10 mounting specifications.
  4. Gradually ramp‑up system pressure during commissioning. Inspect for leakage and abnormal noise before switching to full‑load operation. Verify cable‑break‑protection function by simulating signal disconnection.

Safety Precautions

  1. Retain manual hydraulic override for backup safety during system retrofits.
  2. Fit pressure‑relief valves in the hydraulic circuit for overpressure protection.
  3. Implement emergency‑stop logic to de‑energize the proportional valve under fault conditions.
  4. Ensure hoses and hydraulic connections are rated for the system's maximum working pressure.

 

 

 

FAQ

 

 

Q: What is the maximum transmission distance for the 4‑20 mA F1 signal?

A: With standard 24 VDC supply and 1.5 mm² shielded twisted‑pair cable, stable signal transmission can reach up to 500 meters for large‑workshop layouts. Keep total loop resistance ≤500 Ω.

Q: Does 4WRPEH10 F1 support cable‑break protection?

A: Yes. Built‑in cable‑break monitoring triggers output‑stage shutdown when input current drops below 2 mA, preventing uncontrolled equipment movement and improving machine safety.

Q: What differentiates 4WRPEH10 F1 from 4WRPEH6 F1?

A: 4WRPEH10 F1 is NG10 large‑flow variant (50‑100 L/min) for medium‑large hydraulic machinery. 4WRPEH6 F1 is NG6 small‑flow (4‑40 L/min) for compact precision equipment. Both share <10 ms response and optional IO‑Link capability.

Q: Can IO‑Link be retrofitted on‑site for standard F1‑version valves?

A: IO‑Link hardware is factory‑integrated during manufacturing. Please specify IO‑Link requirement at order placement; field retrofitting is not supported.

Q: What about warranty and lead‑time?

A: All standard valves carry a 12‑month quality warranty from delivery date plus lifelong technical consultation. Standard 4WRPEH10 F1 configurations ship within 2‑4 weeks after order confirmation.

 

 

 

Ready to Get a Quote?

 

 

Send us your required model, quantity and application details, and our team will reply within 24 hours with a formal quotation.

Send Inquiry Now

 

Hot Tags: 4WRPEH10 F1 High‑Speed Proportional Directional Valve
4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection, China 4WRPEH10 F1 High‑Speed Proportional Directional Valve
4‑20mA Current‑Loop Control | NG10 Size | Cable‑Break Protection manufacturers, Direct Acting Hydraulic Proportional Valve 4WRPEH10 A1 10V Control, 4wrpeh, Direct Acting Hydraulic Proportional Valve 4WRPEH6 A1 10V Control, 4WRPEH10 High Response Hydraulic Valve, Ng6 Proportional Valve, Direct Acting Hydraulic Proportional Valve 4WRPEH6 F1 4 20mA Control

Send Inquiry