4WRPE10 F1 Proportional Directional Valve
4-20mA Current Loop Control | NG10 Size | Cable Break Protection

4WRPE10 F1 Proportional Directional Valve <br>4-20mA Current Loop Control | NG10 Size | Cable Break Protection
Details
BOKIN 4WRPE10 F1 is a direct-operated proportional directional valve with integrated OBE and 4-20mA current loop control. Featuring built-in cable break monitoring and strong electromagnetic interference resistance, it ensures stable signal transmission over long wiring distances. It matches the dimensional and hydraulic specifications of equivalent Rexroth 4WRPE10 F1 configurations.

Core Specifications:
NG10 Size | 160 L/min Max Flow | 4-20mA F1 Interface | Cable Break Monitoring | 350 Bar | 12-Month Warranty
Category
Type 4WRPE Proportional Valve
Share to
Send Inquiry
Product Details

Bokin Electro-Hydraulic Technology (Foshan) Co., Ltd. is one of the leading manufacturers and suppliers of 4wrpe10 f1 proportional directional valve
4-20ma current loop control | ng10 size | cable break protection in China. If you're going to wholesale bulk durable 4wrpe10 f1 proportional directional valve
4-20ma current loop control | ng10 size | cable break protection made in China, welcome to get pricelist from our factory. All customized products are with high quality and competitive price.

 

 

Key Specifications At a Glance

 

 

Parameter Value
Nominal Size NG10 (Component Series 3X)
Mounting Standard ISO 4401-05-04-0-05
Max Operating Pressure (A/B/P ports) 350 bar
Max Operating Pressure (T port) 200 bar
Max Summated Flow 160 L/min
Rated Flow (Δp = 5 bar per control edge) 50 / 80 L/min
Control Signal F1 interface, 4 – 20 mA current loop input
Cable Break Monitoring Yes (triggered below 2 mA, output shutdown)
Hysteresis < 0.25%
Response Sensitivity < 0.05%
Supply Voltage 24 VDC (19 – 36 VDC range)
Protection Class IP65 (correctly mounted connector)
Ambient Temperature -20°C to +60°C
CE Compliance MD 2006/42/EC, EMC Directive 2014/30/EU

 

 

 

Available Configurations

 

 

Select the flow rating and spool type for your system:

 

Model Number

Rated Flow

Spool Type

Quick Action

4WRPE 10 E50SJ-3X/M/24F1 50 L/min Standard zero-overlap (E)

Inquire Now

4WRPE 10 E50SJ-3X/V/24F1 50 L/min Standard zero-overlap (E)

Inquire Now

4WRPE 10 E1-50SJ-3X/M/24F1 50 L/min Injection molding special (E1)

Inquire Now

4WRPE 10 E1-50SJ-3X/V/24F1 50 L/min Injection molding special (E1)

Inquire Now

4WRPE 10 W6-50SJ-3X/M/24F1 50 L/min Positive-overlap (W6)

Inquire Now

4WRPE 10 W6-50SJ-3X/V/24F1 50 L/min Positive-overlap (W6)

Inquire Now

4WRPE 10 V50S-3X/M/24F1 50 L/min Pressure-compensated (V)

Inquire Now

4WRPE 10 V50S-3X/V/24F1 50 L/min Pressure-compensated (V)

Inquire Now

4WRPE 10 E80SJ-3X/M/24F1 80 L/min Standard zero-overlap (E)

Inquire Now

4WRPE 10 E80SJ-3X/V/24F1 80 L/min Standard zero-overlap (E)

Inquire Now

4WRPE 10 E1-80SJ-3X/M/24F1 80 L/min Injection molding special (E1)

Inquire Now

4WRPE 10 E1-80SJ-3X/V/24F1 80 L/min Injection molding special (E1)

Inquire Now

4WRPE 10 W6-80SJ-3X/M/24F1 80 L/min Positive-overlap (W6)

Inquire Now

4WRPE 10 W6-80SJ-3X/V/24F1 80 L/min Positive-overlap (W6)

Inquire Now

4WRPE 10 W8-80SJ-3X/M/24F1 80 L/min Positive-overlap (W8)

Inquire Now

4WRPE 10 W8-80SJ-3X/V/24F1 80 L/min Positive-overlap (W8)

Inquire Now

4WRPE 10 EA80SJ-3X/M/24F1 80 L/min Proportional (EA)

Inquire Now

4WRPE 10 EA80SJ-3X/V/24F1 80 L/min Proportional (EA)

Inquire Now

4WRPE 10 V80S-3X/M/24F1 80 L/min Pressure-compensated (V)

Inquire Now

4WRPE 10 V80S-3X/V/24F1 80 L/min Pressure-compensated (V)

Inquire Now

4WRPE 10 V1-80S-3X/M/24F1 80 L/min Pressure-compensated (V1)

Inquire Now

4WRPE 10 V1-80S-3X/V/24F1 80 L/min Pressure-compensated (V1)

Inquire Now

4WRPE 10 Q3-80S-3X/M/24F1 80 L/min Q3 progressive

Inquire Now

4WRPE 10 Q3-80S-3X/V/24F1 80 L/min Q3 progressive

Inquire Now

4WRPE 10 Q5-80S-3X/M/24F1 80 L/min Q5 progressive

Inquire Now

4WRPE 10 Q5-80S-3X/V/24F1 80 L/min Q5 progressive

Inquire Now

 

Need a custom spool profile or special configuration? Send us your requirements → Get Custom Solution

 

 

 

Product Key Advantages

 

1. Strong Anti-Interference for Long-Distance Wiring

The 4-20mA current loop signal maintains stable transmission even over hundreds of meters, immune to electromagnetic interference from frequency converters and motors. Ideal for large workshops, metallurgical plants and long production lines.

2. Built-In Cable Break Safety Protection

Integrated cable break monitoring automatically shuts off the output stage when the signal current drops below 2 mA, preventing uncontrolled equipment movement and reducing operational risks in harsh industrial environments.

3. Direct-Acting Energy-Saving Structure

No pilot oil supply required, simplifying system design and reducing energy consumption. Compact direct-acting construction delivers fast dynamic response with minimal pressure drop, suitable for medium-flow hydraulic circuits.

4. Straightforward System Interchangeability​​​​​​​

Manufactured strictly to ISO 4401 NG10 standard with identical port dimensions and F1 interface pin assignments to equivalent Rexroth 4WRPE10 F1 valves. Installs directly into existing compatible manifolds without re-machining.

 

 

 

Compatibility Reference

 

 

Corresponding Rexroth Model

BOKIN Equivalent Model

Core Match Points

4WRPE 10 E50SJ-3X/M/24F1 4WRPE 10 E50SJ-3X/M/24F1 Same mounting dimensions, current interface, hydraulic performance
4WRPE 10 E50SJ-3X/V/24F1 4WRPE 10 E50SJ-3X/V/24F1
4WRPE 10 E1-50SJ-3X/M/24F1 4WRPE 10 E1-50SJ-3X/M/24F1
4WRPE 10 E1-50SJ-3X/V/24F1 4WRPE 10 E1-50SJ-3X/V/24F1
4WRPE 10 W6-50SJ-3X/M/24F1 4WRPE 10 W6-50SJ-3X/M/24F1
4WRPE 10 W6-50SJ-3X/V/24F1 4WRPE 10 W6-50SJ-3X/V/24F1
4WRPE 10 V50S-3X/M/24F1 4WRPE 10 V50S-3X/M/24F1
4WRPE 10 V50S-3X/V/24F1 4WRPE 10 V50S-3X/V/24F1
4WRPE 10 E80SJ-3X/M/24F1 4WRPE 10 E80SJ-3X/M/24F1
4WRPE 10 E80SJ-3X/V/24F1 4WRPE 10 E80SJ-3X/V/24F1
4WRPE 10 E1-80SJ-3X/M/24F1 4WRPE 10 E1-80SJ-3X/M/24F1
4WRPE 10 E1-80SJ-3X/V/24F1 4WRPE 10 E1-80SJ-3X/V/24F1
4WRPE 10 W6-80SJ-3X/M/24F1 4WRPE 10 W6-80SJ-3X/M/24F1
4WRPE 10 W6-80SJ-3X/V/24F1 4WRPE 10 W6-80SJ-3X/V/24F1
4WRPE 10 W8-80SJ-3X/M/24F1 4WRPE 10 W8-80SJ-3X/M/24F1
4WRPE 10 W8-80SJ-3X/V/24F1 4WRPE 10 W8-80SJ-3X/V/24F1
4WRPE 10 EA80SJ-3X/M/24F1 4WRPE 10 EA80SJ-3X/M/24F1
4WRPE 10 EA80SJ-3X/V/24F1 4WRPE 10 EA80SJ-3X/V/24F1
4WRPE 10 V80S-3X/M/24F1 4WRPE 10 V80S-3X/M/24F1
4WRPE 10 V80S-3X/V/24F1 4WRPE 10 V80S-3X/V/24F1
4WRPE 10 V1-80S-3X/M/24F1 4WRPE 10 V1-80S-3X/M/24F1
4WRPE 10 V1-80S-3X/V/24F1 4WRPE 10 V1-80S-3X/V/24F1
4WRPE 10 Q3-80S-3X/M/24F1 4WRPE 10 Q3-80S-3X/M/24F1
4WRPE 10 Q3-80S-3X/V/24F1 4WRPE 10 Q3-80S-3X/V/24F1
4WRPE 10 Q5-80S-3X/M/24F1 4WRPE 10 Q5-80S-3X/M/24F1
4WRPE 10 Q5-80S-3X/V/24F1 4WRPE 10 Q5-80S-3X/V/24F1

More models are available; please contact us for additional model options.

 

Note: For system configuration reference only. BOKIN is an independent brand. Please verify specifications before installation.

 

 

 

Typical Applications

 

 

  • Metallurgical equipment and long production lines
  • Large die casting machines with remote control cabinets
  • Heavy-duty metal forming presses
  • Outdoor hydraulic equipment and mining machinery
  • Workshop hydraulic systems with long wiring distances
  • Industrial sites with high electromagnetic interference

 

Prefer voltage control for higher precision?

View 4WRPE10 A1 (±10V) →

 

 

 

Installation & Commissioning Guidelines

 

Installation Notes

  1. Thoroughly clean all oil ports and connecting surfaces before installation to prevent contaminants from entering the valve body.
  2. Confirm the control signal type (4–20mA current) and power supply voltage match the valve nameplate specifications before wiring.
  3. Tighten mounting bolts evenly to the recommended torque (12.5–15 Nm for M6 screws) to avoid valve body deformation and internal leakage.
  4. Gradually increase system pressure during commissioning. Monitor for leaks and abnormal noise before full-load operation.

Safety Precautions

  1. Install pressure relief valves in the hydraulic circuit to protect against overpressure.
  2. Add an emergency stop circuit that de-energizes the proportional valve in emergency situations.
  3. Ensure all hydraulic connections and hoses are rated for your system's maximum working pressure.

 

 

 

FAQ

 

 

Q: What is the maximum transmission distance for the 4-20mA signal?

A: Under standard 24VDC power supply and 1.5mm² cable, the signal transmits stably up to 500 meters, fully meeting the layout requirements of large workshops and long production lines.

Q: Does the F1 valve have cable break protection?

A: Yes. When the signal current drops below 2 mA, the output stage automatically shuts off to ensure equipment and operator safety.

Q: Do you provide on-site installation guidance?

A: Yes. We offer remote technical guidance for all standard orders, and on-site commissioning support for bulk project orders.

Q: What is the warranty period?

A: All standard valves come with a 12-month quality warranty from the delivery date, with lifelong technical consultation support.

 

 

 

Ready to Get a Quote?

 

 

Send us your required model, quantity and application details, and our team will reply within 24 hours with a formal quotation.

Send Inquiry Now

Hot Tags: 4wrpe10 f1 proportional directional valve
4-20ma current loop control | ng10 size | cable break protection, China 4wrpe10 f1 proportional directional valve
4-20ma current loop control | ng10 size | cable break protection manufacturers, 4wrz, Hydraulic Proportional Valve 4WRZ10, Hydraulic Proportional Valve 4WRZ32, Pilot Operated Hydraulic Proportional Valve 4WRZ16, Pilot Operated Hydraulic Proportional Valve 4WRZ25, Pilot Operated Hydraulic Proportional Valve 4WRZ32

Send Inquiry