Reading a hydraulic pump datasheet correctly requires understanding which numbers actually matter for long-term reliability - and which are theoretical limits that should never be sustained in practice.
Pressure ratings:
Three pressure values appear on pump specifications: working pressure, rated pressure, and maximum (peak) pressure. The critical mistake is treating rated pressure as the normal operating target. Rated pressure is the pressure at which the pump can operate continuously for its rated service life under specified conditions. In real applications, long-term working pressure should be maintained 20-30% below the rated value. This margin accounts for pressure spikes during valve switching, transient conditions during cycle transitions, and the cumulative effect of wear on internal clearances.
Displacement versus flow:
Displacement (cc/rev) is a geometric parameter - the volume of oil the pump moves per revolution, independent of speed. Flow rate (L/min) is displacement multiplied by rotational speed. When sizing a pump for an application, calculate the required flow based on actuator speed requirements, then add approximately 10% margin to account for internal leakage and system losses. Selecting a pump with flow capacity exactly matching calculated demand leaves no room for efficiency degradation as the pump ages.
Efficiency:
Total pump efficiency is the product of volumetric efficiency (how much oil actually flows out versus theoretical) and mechanical efficiency (how much input power transfers to hydraulic power). Both decline with wear. For Rexroth Type axial piston pumps such as A4VSO and A2FO series, a new pump typically achieves total efficiency above 90%. When total efficiency drops below 80%, the pump is wasting energy as heat - and that heat accelerates oil degradation, seal hardening, and further efficiency loss in a compounding spiral.
For internal gear pumps, volumetric efficiency is particularly sensitive to the clearance between the gear teeth and the internal housing. As this clearance increases with wear, internal leakage rises and effective flow drops - even when the pump sounds normal during operation.
The practical takeaway: monitor efficiency trends, not just absolute values. A pump losing 2-3% efficiency per quarter is a maintenance candidate, regardless of current output levels.